Technical Paper
Load Control for an HCCI Engine
2005-04-11
2005-01-0150
Homogeneous-Charge-Compression-Ignition (HCCI) engine operation in a vehicle drive cycle is a very dynamic process. In this paper, a controller is devised on the premise that the vehicle is operating under Drive-By-Wire so that the driver commands the engine torque output according to the perceived vehicle speed. Thus a load-following controller is appropriate. Such a controller was developed for a single cylinder engine with electromagnetic variable valve timing control (also known as Controlled-Auto-Ignition (CAI) operation). Under open-loop operation within the CAI regime, the results indicated that the engine response was bipolar in nature: (a) the engine either responded quasi-statically to the open-loop control, or (b) the CAI combustion failed. The latter happened in a load increase process in which the per-cycle increment was too high.